Rosemount 3144P Pressure Sensor Transmitter With Percent Range Graph Buttons / Switches

Large Image :  Rosemount 3144P Pressure Sensor Transmitter With Percent Range Graph Buttons / Switches

Product Details:

Place of Origin: America
Brand Name: Rosemount
Model Number: 3144P Temperature Transmitter

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 5-8 work days
Payment Terms: T/T
Supply Ability: 100
Detailed Product Description
Brand: Rosemount Model: 3144P Temperature Transmitter
Origion: America Housing: Dual-compartment Field Mount
Display/Interface: Large LCD Display Output Signal: 4-20 MA /HART®
Input: Dual And Single Sensor
High Light:

differential pressure flow transmitter

,

high temperature differential pressure transmitter

 

Rosemount™ 3144P Temperature Transmitter Large LCD display with percent range graph and buttons/switches

 

 

The Rosemount 3144P Temperature Transmitter provides industry-leading accuracy, stability and reliability for your temperature measurements. It features a dual-compartment housing to ensure reliability and advanced diagnostics to keep your measurement point up and running. When combined with Rosemount X-well Technology and the Rosemount 0085 Pipe Clamp sensor, this transmitter can provide accurate measurement of process temperature, eliminating the need for a thermowell or process penetration.

 

 

Specifications

 

Input Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal 4-20 mA /HART® protocol, FOUNDATION™ Fieldbus protocol
Housing Dual-compartment field mount
Display/Interface Large LCD display with percent range graph and buttons/switches
Diagnostics Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking

Calibration Options

Transmitter-sensor matching (Callendar-Van Dusen constants), custom trim
Certifications/Approvals

SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications

 

 

 

 

 

 

Features

  • Industry-leading accuracy and reliability for best performance in critical control and safety applications
  • Transmitter-sensor matching improves measurement accuracy up to 75%
  • 5-year long-term stability extends calibration intervals to reduce trips to the field
  • Rosemount X-well Technology measures temperature without a process penetration for reduced design, installation and maintenance costs
  • Dual compartment housing provides superior protection in harsh environments
  • Hot Backup™ capability and sensor drift alert utilizing dual sensors ensure measurement integrity
  • Thermocouple degradation diagnostic monitors thermocouple health to detect degradation before failure
  • Minimum and maximum temperature tracking allows monitoring of temperature extremes for easy troubleshooting
  • Transmitter supports multiple protocols for integration in many host environments across many industries
  • Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting

 

 

 

CHALLENGE

 

Traditional insertion-style temperature measurement points using thermowells are challenging to design and specify, complex and time consuming to install and present many project risks.

 

Surface point measurements do not meet the specified performance requirements.

 

 

OUR SOLUTION

 

Rosemount X-well Technology provides a complete point solution for accurately measuring process temperature without the requirement of a thermowell or process penetration. This capability simplifies temperature measurement point specification and installation, while reducing start up time and lowering project risk.

 

 

HOW IT WORKS

 

Rosemount X-well Technology calculates a repeatable, accurate internal process temperature measurement based on thermal conductivity properties of the temperature assembly and process piping.

 

 

The Rosemount 3144P Temperature Transmitter or 648 Wireless Temperature Transmitter can be ordered with Rosemount X-well Technology via the “PT” model code option and must be factory configured with the addition of the “C1” model option code which requires user supplied information of process pipe material and pipe schedule. When using Rosemount X-well Technology, the Rosemount 3144P or 648 is required to be assembled to the Rosemount 0085 Pipe Clamp RTD Sensor in a direct mount configuration.

 

 

 

 

 

Contact Details