Shenzhen Wisdomlong Technology CO.,LTD

 

Work hard and best service for you!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsRedundant Power Supply Module

Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200

Superb delivery a great product, perfect communication as well !! A++++

—— Carlos

Great deal. Fast shipping and good service.Recommended !!!!!!!!!

—— Gita

I'm Online Chat Now

Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200

Large Image :  Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200

Product Details:

Place of Origin: FR
Brand Name: Schneider
Model Number: 140NPR31200

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, Western Union
Supply Ability: 100
Detailed Product Description
Brand: Schneider Model: 140NPR31200
Palce Of Origin: FR Type: Redundant
Rack Slot: 1 Typical: 760 MA
Weight: 1 Kg
High Light:

plc power supply module

,

diode redundancy module

Redundant Power Supply Module SCHNEIDER TSX QUANTUM MODICON 140NPR31200​
 

 
 
 
General Specifications

Item 140 NRP 312 00 140 NRP 312 01
power consumption in backplane (5VDC)
Typical: 760 mA
Maximum: 1000 mA
Typical: 760 mA
Maximum: 1000 mA
wavelength 1310 nm 1310 nm
fiber 50/125 µm
62.5/125 µm
9/125 µm
expansion 0-2 km 0-15 km

 

 

Optical Transmitter Specifications

optical power –23.5...–14 dBm with 50/125 µm fibercable
–20...–15 dBm with 62.5/125 µm fibercable
–15...–8 dBm with 9/125 µm fiber cable
rise / fall time 3 nsec or better 2.5 nsec or better
transmitter disable offpower
–45 dBm –45 dBm

 

 

Mechanical Specifications

weight 1 kg (2 lb) max
dimensions (h x d x w) 250 x 103.85 x 40.34 mm (9.84 x 4.09 x 1.59 in)
material (enclosures and bezels) polycarbonates
space requirements 1 rack slot

 

 

Operating Conditions

RFI immunity (IEC 1000-4-3) 80...1000 MHz, 10 V/m
surge (IEC 1000-4-5) 1 kV shield to ground
electrostatic discharge (IEC 1000-4-2) 8 kV air / 4 kV contact
dielectric strength field to bus: 1400 Vdc
channel to channel: 500 Vdc

 

 

Operating Conditions

temperature 0...60 ° C (32...140 °F)
humidity 90...95% RH non-condensing at 6 ° C
chemical interactions Enclosures and terminal strips are made of polycarbonates. This material can be
damaged by strong alkalis and various hydrocarbons, esters, halogens and
ketones in combination with heat. Common products containing these include
detergents, PVC products, petroleum products, pesticides, disinfectants, paint
removers, and spray paints.
altitude 2,000 m. When the altitude exceeds this, reduce the 60 ° C maximum operating
temperature by 6 ° C/1000 m of additional elevation.
vibration 10...57 Hz at 0.075 mm constant displacement amplitude 57...150 Hz at 1 g
shock +/-15 g peak, 11 ms, half-sine wave

 

 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
 
 
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
 
 
 
 

Similar Products

140ERT85410 140ESI06210 140HLI34000 140MSB10100
140MSC10100 140NOA61100 140NOE31100 140NOE35100
140NOE51100 140NOE55100 140NOE77101 140NOE77110
140NOL91100 140NOL91120 140NOM21100 140NOM21200 
140SHS94500 140XBE10000 140XBP00200 140XBP00300
140XBP00400 140XBP00600 140XBP01000 140XBP01600
140XCA10206 140XCA10215 140XCA71703 140XCA71700
140XCA71709 140XCP20000 140XCP40100 140XCP40200
140XCP50000 140XCP51000 140XCP60000 140XCP90000
140XSM00200 140XSM01000 140XTS00100 140XTS00200
140XTS00209 140XTS00212 140CFU00600  140NOM25200
140XTS00500 140XTS01203 140XTS01206 140XTS01209
140XTS01212 140XTS10206 140XTS10215 140XTS33200
140ACO02000 140ACO13000 140AII33000 140AII33010
140AIO33000 140AMM09000 140ARI03010 140ATI03000

140AVI03000 140AVO02000 140CFA04000 140CFB03200
140CFC03200 140CFD03200 140CFE03200 140CFG01600
140CFH00800 140CFI00800 140CFJ00400 140CFK00400

 

 

 

 

 

 

          Warning 

UNINTENDED EQUIPMENT OPERATION Do not connect a 140 NRP 312 01 single-mode fiber converter module to a 140 NRP 312 00 multi-mode fiber converter module. Failure to follow these instructions can result in death, serious injury, or equipment damage.

 

 

 

140 NRP 312 00/01 fiber converter modules are an alternative method to using a dual-ring switch
(DRS) to provide fiber optic communications in a Quantum EIO system. You can install 140 NRP 312 00/01 modules on Quantum local and RIO drops to:
l extend the total length of the Quantum EIO network (RIO drops in separate areas of a factory that are more than 100 m apart)
l improve noise immunity
l resolve possible grounding issues when using different grounding methods is required between 2 buildings You can connect a 140 NRP 312 00/01 module to any 100Mbps-based Ethernet module on a Quantum rack to extend the transmission distance. Examples:
l You can connect a 140 NRP 312 00/01 module to a 140 CRP 312 00 RIO head module or a 140 CRA 312 0• RIO adapter module in a Quantum EIO system.
l You can connect a 140 NRP 312 00/01 module to a 140 NOC 780 00 DIO head module to manage DIO devices. There are 2 models of fiber converter modules, each supporting one type of fiber cable:
l 140 NRP 312 00 supports multi-mode fiber cable.
l 140 NRP 312 01 supports single-mode fiber cable.
For details on other fiber converter modules and how they operate within Quantum and M340 networks, refer to the 140 NRP 954 00/01C Fiber Optic Repeater Modules User Guide and the BMX NRP 0200/01 Fiber Converter Module User Guide.

 

 

 

Introduction

140 NRP 312 00/01 fiber converter modules have 2 copper ports and 2 fiber ports. The fiber ports, in both multi-mode and single-mode modules, use LC-type connectors. One fiber port is used as the transmitter signal (Tx), and the other fiber port is used as the receiver signal (Rx). There are 2 models of fiber converter modules, each supporting one type of fiber cable:  140 NRP 312 00 supports multi-mode fiber cable.  140 NRP 312 01 supports single-mode fiber cable.

 

 

 

140 NRP 312 00/01 Description

The following figure shows the 140 NRP 312 00/01 fiber converter module:

 

1 model number, description code, color code

2 LEDs

3 removable door

4 customer identification label (Fold label and place it inside door.)

5 Ethernet port 1

6 Ethernet port 2

7 fiber port 1
8 fiber port 2


NOTE:There are 2 separate pairs:
l pair 1: Ethernet port 1 + fiber port 1
l pair 2: Ethernet port 2 + fiber port 2

 

 

 

Installing Fiber Converter Modules to Extend Distance Between the Local Rack and an RIO Drop

The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m.

 

 

 

 

1 140 NRP 312 00/01 fiber converter module interlinked with the 140 CRP 312 00 RIO head module on the local rack
2 RIO drop with a 140 NRP 312 00/01 fiber converter module interlinked with a 140 CRA 312 •0 RIO
adapter for fiber cable connection
3 RIO drop without a 140 NRP 312 00/01 fiber converter module for copper cable connection
4 fiber cable on the main ring used for distances greater than 100 m
5 copper cable on the main ring used for distances less than 100 m

 

 

Installing Fiber Converter Modules to Extend Distance Between RIO Drops

The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m.

 

 

1 140 NRP 312 00/01 fiber converter module interlinked with the 140 CRP 312 00 RIO head module on thelocal rack
2 RIO drop with a 140 NRP 312 00/01 fiber converter module interlinked with a 140 CRA 312 •0 RIO adapter for fiber cable connection
3 RIO drop without a 140 NRP 312 00/01 fiber converter module for copper cable connection
4 fiber cable on the main ring used for distances greater than 100 m
5 copper cable on the main ring used for distances less than 100 m

 

 

Installing Fiber Converter Modules to Extend Distance Between DIO Devices

The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between DIO devices beyond 100 m.

 

1 Quantum CPU on the primary local rack
2 Quantum CPU on the standby local rack
3 140 CRP 312 00 RIO head module on the primary local rack
4 140 CRP 312 00 RIO head module on the standby local rack
5 140 NOC 780 00 DIO head module interlinked with the 140 CRP 312 00 module (3) and the
140 NRP 312 00/01 fiber converter module (7) on the primary local rack
6 140 NOC 780 00 DIO head module interlinked with the 140 CRP 312 00 module (4) and
the140 NRP 312 00/01 fiber converter module (8) on the standby local rack
7 140 NRP 312 00/01 fiber converter module interlinked with the 140 NOC 780 00 DIO head module (5) on
the primary local rack
8 140 NRP 312 00/01 fiber converter module interlinked with the 140 NOC 780 00 DIO head module (6) on
the standby local rac
9 fiber sync-link connecting the primary and standby CPUs (1 & 2)
10 fiber sync-link connecting the primary and standby 140 CRP 312 00 modules (3 & 4)
11 fiber sync-link connecting the primary and standby 140 NRP 312 00/01 modules (7 & 8)
12 fiber cable on the main ring used for distances greater than 100 m
13 dual-ring switch (DRS) used to connect DIO devices (14) to the main ring
14 DIO device
15 copper cable on the main ring used for distances less than 100 m

 

 

 

Installing Fiber Converter Modules in a Hot Standby System

The following figure shows a Quantum EIO Hot Standby network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m. The use of fiber converter modules are useful to help avoid noise, attenuation, and/or distant grounding when the distance between the primary and standby PLCs exceeds 100 m.

 

 

1 Quantum CPU on the primary local rack
2 Quantum CPU on the standby local rack
3 140 NRP 312 0• fiber converter module interlinked with the 140 CRP 312 00 RIO head module on the
primary local rack
4 140 NRP 312 0• fiber converter module interlinked with the 140 CRP 312 00 RIO head module on the
standby local rack
5 fiber sync-link connecting the primary and standby CPUs
6 fiber sync-link connecting the primary and standby 140 NRP 312 0• fiber converter modules
7 fiber main ring
8 Quantum RIO drop
9 X80 RIO drop

 

Contact Details
Shenzhen Wisdomlong Technology CO.,LTD

Contact Person: Anna

Tel: 86-13534205279

Send your inquiry directly to us Message not be empty!