Shenzhen Wisdomlong Technology CO.,LTD

 

Work hard and best service for you!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsDigital I O Module

BENTLY NEVADA 350033 16 Channel Relay Module PWA 149986-01 D 40 °C to +85 °C

Superb delivery a great product, perfect communication as well !! A++++

—— Carlos

Great deal. Fast shipping and good service.Recommended !!!!!!!!!

—— Gita

I'm Online Chat Now

BENTLY NEVADA 350033 16 Channel Relay Module PWA 149986-01 D 40 °C to +85 °C

Large Image :  BENTLY NEVADA 350033 16 Channel Relay Module PWA 149986-01 D 40 °C to +85 °C

Product Details:

Brand Name: Bently Nevada
Model Number: 128229-01

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, Western Union
Detailed Product Description
Place Of Origin: USA Brand: Bently Nevada
Model: 128229-01 Model 2: 12822901
Series: 3500 Weight: 1.0 Pounds
High Light:

digital input output module

,

plc i o modules

BENTLY NEVADA 350033 16 Channel Relay Module PWA 149986-01 D 40 °C to +85 °C

 

 

 

 

 

Description
The 16-Channel Relay Module is a full-height module that provides 16 relayoutputs. Any number of 16-Channel Relay Modules can be placed in any of theslots to the right of the Rack Interface Module. Each output of the 16-ChannelRelay Module can be independently programmed to perform needed voting
logic.


Each relay utilized on the 16-Channel Relay Module includes "Alarm Drive Logic".Programming for the Alarm Drive Logic uses AND and OR logic, and can use alarming inputs (Alert and Danger statuses), Not- OK, or individual PPLs from any monitor channel or any combination of monitor channels in the rack. Users
program this Alarm Drive using the 3500 Rack Configuration Software to meet the specific needs of the application.


Note: Triple Modular Redundant (TMR) applications must use the 3500/34 TMR Relay Module.
Consult the specification and ordering Information for the 3500/34 for details.

 

 

 

Estimated Shipping Size
Dimensions: 1" x 11" x 10" (3 cm x 28 cm x 25 cm)
Weight: 1 lbs 10 oz (0.74 kg)

 

 


 
 
OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
 
 
 
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
 
 
 
 
Similar  Products:

33018051-05 33018050-05

330180-90-00 330180-91-05

33018090-05 330780-50-00

330780-90-00 330850-91-05

330850-90-05 330850-50-05

330980-70-00 330980-50-00

330980-51-00 330195-02-1210-00

330930-060-0-05 330930-060-01-00

330130-070-01-00 330130-080-03-00

330130085-00 -330130-085-01-00

330130-080-0-00 330130-080-01-00

330130040-01-00 330130-045-00 -00

330130045-01-00 330130040-01-05

330130040-03-00 330130040-00 -00

330130045-05-05 330130040-02-00

330130-070-03-00 330130-045-03-05

330130080-00 -05 33085 4-040-25-05

33084-080-2405 330190-080-01-00

330930-060-01-00 330930-045-00 -05

330930040-00 -330930-045-01-00

330730-4040-00 -330730-040-01-00

330730-080-0-00 330730-080-01-00

330730040-03-00 330130-080-13-00

130713-02-50-01 130118-0100-02

 
 
 
 
 
 
 
 
1. 3500 monitors ordered with the multiple approvals option (-02) are certified to Zone 2 standards (including ATEX and North American Zones). The Zone 2 standards specify increased spacing requirements at higher voltages, and the 3500/33 relays do not meet these spacing requirements. For this reason, 3500/33 relays ordered with the multiple approvals option have historically been limited to a lower voltage than those ordered with the other approvals options. Using higher voltages would violate the hazardous area certificates associated with the multiple approvals option. (The North American Division 2 standards associated with the CSA-only approvals option (-01) have been de-rated to 30Vrms to comply with 61010-1 type test requirements.)
 

2. If the 3500/33 is part of a functional safety (SIL) system, the functional safety certificate requires the restricted voltage. Higher voltages are not allowed for functional safety (SIL) systems.
 

3. It is possible to connect field wiring to the 3500/33 relays such that conductors are exposed to potential human contact. This could present a shock hazard at high voltages. Customers should only use the 3500/33 relay at voltages up to 30 Vrms. Appropriate safety precautions should be taken with respect to the shock hazard.
 
 
 
 
 
Ordering Considerations
• The 3500/33 requires 3500 Rack Configuration software, version 3.3 or later
• The 3500/33 requires 3500 Data Acquisition software, version 2.40 or later
• The 3500/33 requires 3500 Data Display software, version 1.40 or later
• When used with a 3500/93 LCD Display module, the 3500/93 will require firmware revision P or later.
• When used with a 3500/94 VGA Display module, the 3500/94 will require firmware revision C or later
 

Contact Details
Shenzhen Wisdomlong Technology CO.,LTD

Contact Person: Anna

Tel: 86-13534205279

Send your inquiry directly to us Message not be empty!