Shenzhen Wisdomlong Technology CO.,LTD

 

Work hard and best service for you!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsRedundant Power Supply Module

Schneider Electric Sepam 59704 SEP383 Memory 59707 MMS020 series 80 with firmware V07.20

Superb delivery a great product, perfect communication as well !! A++++

—— Carlos

Great deal. Fast shipping and good service.Recommended !!!!!!!!!

—— Gita

I'm Online Chat Now

Schneider Electric Sepam 59704 SEP383 Memory 59707 MMS020 series 80 with firmware V07.20

Large Image :  Schneider Electric Sepam 59704 SEP383 Memory 59707 MMS020 series 80 with firmware V07.20

Product Details:

Place of Origin: FR
Brand Name: Schneider
Model Number: 59704 SEP383

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, Western Union
Supply Ability: 100
Detailed Product Description
Brand: Schneider Model: 59704 SEP383
Palce Of Origin: FR Series: Quantum CPUs
Marking: CE Checks: Process Control
Clock Frequency: 166 MHz Weight: 2bl
High Light:

analog interface module

,

diode redundancy module

Schneider Electric Sepam 59704 SEP383 Memory 59707 MMS020 series 80 with firmware V07.20

 

 

 

Specifications

Main
range of product
Sepam series 80
device short name
SEP383
user machine interface type
Advanced
Complementary
UMI indication
Status of logic inputs
Logipam data
Metering and diagnosis data
Main protection settings
Version of Sepam and remote modules
List of activated protection functions
Alarms and operating messages
UMI control
Alarm acknowledgement
Output testing
Sepam reset
display resolution
128 x 64 pixels
number of key
9
local signalling
2 LEDs for Sepam operating status (back part)
2 LEDs for Sepam operating status (front face)
9 LEDs for indication of parameters (front face)
output type
Annunciation relay: 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 1 A cos φ > 0.3
Annunciation relay: 127 V DC continuous current: 2 A breaking capacity: 0.5 A L/R < 20 ms
Annunciation relay: 220 V DC continuous current: 2 A breaking capacity: 0.15 A L/R < 20 ms
Annunciation relay: 24 V DC continuous current: 2 A breaking capacity: 2 A L/R < 20 ms
Annunciation relay: 48 V DC continuous current: 2 A breaking capacity: 1 A L/R < 20 ms
Control relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 5 A cos φ > 0.3 making capacity: < 15 A for 200 ms
Control relay: 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms
Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.5 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.7 A resistive making capacity: < 15 A for 200 ms
Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.1 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.3 A resistive making capacity: < 15 A for 200 ms
Control relay: 24 V DC continuous current: 8 A breaking capacity: 4 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 24 V DC continuous current: 8 A breaking capacity: 6 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 24 V DC continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms
Control relay: 48 V DC continuous current: 8 A breaking capacity: 1 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 48 V DC continuous current: 8 A breaking capacity: 2 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 48 V DC continuous current: 8 A breaking capacity: 4 A resistive making capacity: < 15 A for 200 ms
[Us] rated supply voltage
24/250 V DC tolerance: - 20...10 % maximum consumption: < 16 W
supply inrush current
< 10 A for 10 ms at 24/250 V DC
battery type
Lithium 3.6 V size: 1/2 AA
battery life
10 year(s) (Sepam energized)
8 year(s) (Sepam not energized)
mounting mode
Fixed
mounting support
Plate
height
222 mm
width
264 mm
depth
89.7 mm
net weight
3.62 kg
power frequency dielectric withstand
2 kV during 1 min conforming to IEC 60255-5
1 kV (indication output) during 1 min conforming to ANSI C37.90
1.5 kV (control output) during 1 min conforming to ANSI C37.90
[Uimp] rated impulse withstand voltage
5 kV (1.2/50 µs) conforming to IEC 60255-5
mechanical robustness
Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
Shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
Vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
Vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
Vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
Environment
standards
CSA C22.2 No 14-95
CSA C22.2 No 94-M91
EN 50263
CSA C22.2 No 0.17-00
UL 508
product certifications
UL 508 file N° 212533
CE
C22.2 file N° 210625
fire resistance
650 °C conforming to IEC 60695-2-11
IP degree of protection
Other panels: IP20 conforming to IEC 60529
Front panel: IP52 conforming to IEC 60529
NEMA degree of protection
Type 12 conforming to NEMA
immunity to microbreaks
100 ms
electromagnetic compatibility
Fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4
Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4
Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6
Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8
Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3
Surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV MD, conforming to IEC 61000-4-5
Conducted disturbance emission: (emission tests), conforming to IEC 60255-25
Disturbing field emission: (emission tests), conforming to IEC 60255-25
Disturbing field emission: (emission tests), A, conforming to EN 55022
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3
1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV MD, conforming to IEC 60255-22-1
1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV MD, conforming to ANSI C37.90.1
100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV MD, conforming to IEC 61000-4-12
Conducted disturbance emission: (emission tests), A, conforming to EN 55022
Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2
Voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11
climatic withstand
Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30
Exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1
Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1
Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2
Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2
Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52
Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14
Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
 
 
 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

Contact Details
Shenzhen Wisdomlong Technology CO.,LTD

Contact Person: Anna

Tel: 86-13534205279

Send your inquiry directly to us Message not be empty!