A06B-6140-H015 Fanuc Industrial Servo Drives ALPHA i POWER SUPPLY MODULE MDL AiPS- 15
Description
Part Number: A06B-6140-H015
Description: ALPHA i POWER SUPPLY MODULE MDL AiPS- 15
Product Series: A06B-6140
Description
Fanuc A06B-6140-H015 Alpha I Power Supply Module aiPS-15
Fanuc Alpha i power supply module A06B-6140-H015. PSM-15i in stock and available today. The part is in fully refurbished and tested condition ready to fit and install on your machine tool replacing your faulty A06B-6140-H015 AIPS-15 power module.
CNC offer extensive testing on Fanuc Alpha i power modules, via our 0iMC, 31i control system of which we can ensure that fault finding and testing after repair is done properly rather than assuming that parts might work, etc. Price listed is for exchange only. The H015 belongs to the first generation 6140 series Fanuc Alpha I power supply modules, either as a PSM-15i or AIPS-15 dependent on where the information has originated.
Alarm & error codes
Alarm Code |
Message |
Description |
---|
0 |
|
Unit is ready |
-(dash) |
|
Unit is not ready and could be related to the unit or a machine side cause. |
1 |
PSM-5.5 to PSM-11 |
The main circuit power module (IPM) has detected an overload, over-current, or control supply voltage decrease, over-current, or control supply voltage decrease. Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. |
1 |
PSM-15 to PSM-55 |
Over-current flowed into the input of the main circuit. Input supply voltage imbalance, IGBT defective. |
2 |
|
Internal cooling circuit faulty. |
3 |
|
The temperature of the heat sink has risen. |
4 |
|
DC voltage (DC link) has dropped |
5 |
|
The input power supply is abnormal (open phase) or the main circuit capacitor was not recharged within the specified time. |
6 |
|
The input power supply is abnormal (open phase). |
7 |
|
The DC link voltage is abnormally high. |
8 |
|
The offset of the current detection circuit of the main circuit DC link is excessive. |
8 |
PSMR |
The regenerative discharge unit is heated. |
A |
|
Internal cooling circuit faulty. |
E |
|
The input power supply is abnormal (open phase). |
H |
PSMR |
The temperature of the regenerative resistor has arisen abnormally |
Our advantage Products:
【Honeywell】Module DCS / PLC
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
(Modicon,SMC,SICK,NORGREN,Siemens etc.)
Shenzhen Wisdomlong Technology CO.,LTD
Contact person:Suki
Email:wtl2502keji@163.com
Skype:wtl2502
Company website:www.wtltian.com
Tel:+86-13268302140