Digital Output 24V Redundant Power Supply Module CC-PDOB01 51405043-175 FW G HW G

Large Image :  Digital Output 24V Redundant Power Supply Module CC-PDOB01 51405043-175 FW G HW G

Product Details:

Place of Origin: USA
Brand Name: Honeywell
Model Number: CC-PDOB01

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, Western Union
Supply Ability: 100
Detailed Product Description
Brand: Honeywell Model: CC-PDOB01
Origin Of Place: USA Produc Name: PWA MODULE
Voltage: 24V Channels: 1-8, 9-16, 17-24
Turn-On/Turn-Off Time: 10 Ms (max) Type: Bussed Outpu
High Light:

plc power supply module

,

diode redundancy module

Digital Output 24V Redundant Power Supply Module CC-PDOB01 51405043-175 FW G HW G

 

 

 

QUICK DETAILS

  1. Digital Output
  2. Voltage :24V
  3. 51405043-175

 

 

 

DESCRIPTION

  • Digital Output  Module 
  • PWA  Module 
  • Redundant Power Supply Module 

 

 

SEPCIFICATIONS

 

Parameter Specification
Input / Output Model CC-PDOB01 – 24Volt Digital Output , Field Isolated, Bussed output
IOTA Models CU-PDOB01 – 24Volt Digital Output , Field Isolated, Bussed output
Output Channels 32
Load Voltage 30 VDC Maximum
Galvanic Isolation 1500 VAC RMS or ±1500 VDC
On-State Voltage 24 V (typ), load current @ 0.5A
Off-State Voltage 0v VDC (max) (3.3VDC (max) indicated under no-load condition)
Off-State Leak Current 0.5 μA (max)
Turn-On/Turn-Off Time 10 ms (max)

 

 

 

Relay Digital Output (32 pt):

Digital output with NO or NC dry contacts. Can be used for low power or high power applications.

 

 

Maximum Steady State Load Currentper Output

Current → Voltage
3 A → 250 VAC (resistive)
3 A → 125Maximum Steady State Load Currentper Output VAC (resistive)
3 A → 30 VDC (resistive)
1 A → 48 VDC (resistive)
0.2 A → 125 VDC (resistive)
2 A → 250 VAC (Inductive – 0.4 power factor)
2 A → 125 VAC (Inductive – 0.4 power factor)
1 A → 30 VAC (Inductive L/R = 100 ms)
0.3 A → 48 VAC (Inductive L/R = 100 ms)
0.1 A → 125 VAC (Inductive L/R = 100 ms)

 

 

Contact Life

Operations → % of Max. Load
10,000,000 → (Mechanical Life)
200,000 @ 3 A (100%)
120Ώ + 0.03°F for each channel

 

 

Digital Output Bussed 24 VDC (32 pt):

The Digital Output bussed 24VDC module provides reliable 24V digital output signals to control other processes. The DO24V can support high energy outputs to reduce the number of external components in the output loop.

 

 

 

Parameter Specification              
Input / Output Model CC-PDOB01 – 24Volt Digital Output , Field Isolated, Bussed output  
  CU-PDOB01 – 24Volt Digital Output , Field Isolated, Bussed output  
                 
IOTA Models CC-TDOB11         Non Redundant 6”
                 
  CU-TDOB11         Redundant 12”
                 
Output Channels 32              
                 
Load Voltage 30 VDC Maximum              
             
Load Current     Per Channel   Per 8 Channels Per Module
                 
(A group of 8 channels consists of One Short Condition (1) 0.5A   3A 6A  
   
channels: 1-8, 9-16, 17-24, and 25-32)              
  (1)            
Two Short Condition 0.5A   1.5A 6A  
     
               
               
Galvanic Isolation 1500 VAC RMS or ±1500 VDC          
             
On-State Voltage 24 V (typ), load current @ 0.5A          
     
Off-State Voltage 0v VDC (max) (3.3VDC (max) indicated under no-load condition)  
                 
Off-State Leak Current 0.5 μA (max)              
Turn-On/Turn-Off Time 10 ms (max)              
Gap (0 current) of Output to Field on 10 ms maximum (applies to Redundancy only)    
Switchover                
                 
(1)                
                 

 

One / Two Short Condition parameter denotes the maximum current that can be passed through the DO with the short condition indicated before the short protection mechanism disables the function. As an example, the DO can drive a maximum of 1.5A per 8 channels with two channels shorted before the short protection mechanism will disable all 8 channels affected.

 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- Fanuc motor A0-
Rosemount transmitter 3051- Yokogawa transmitter EJA-
 
 
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
 

 

Contact Details
Shenzhen Wisdomlong Technology CO.,LTD

Contact Person: Anna

Tel: 86-13534205279

Send your inquiry directly to us Message not be empty!