logo
Home > Products >
Redundant Power Supply Module
>
Schneider 140 ARI 030 10 Redundant Power Supply Module with 8-Channel Input for Modicon Quantum Automation

Schneider 140 ARI 030 10 Redundant Power Supply Module with 8-Channel Input for Modicon Quantum Automation

Product Details:
Place of Origin: FR
Brand Name: Schneider
Model Number: 140 ARI 030 10
Detail Information
Place of Origin:
FR
Brand Name:
Schneider
Model Number:
140 ARI 030 10
Brand:
Schneider
Model:
140 ARI 030 10
Palce Of Origin:
FR
Type:
Processor/Controller
Analogue Input Number:
8
Module Format:
Standard
Marking:
CE
Weight:
0.3KG
Highlight:

High Light

Highlight:

plc power supply module

,

diode redundancy module

Trading Information
Minimum Order Quantity:
1
Price:
negotiable
Packaging Details:
New in original box
Delivery Time:
2-3 work days
Payment Terms:
T/T,Western Union
Supply Ability:
100
Product Description
Automation PLC Power Supply Module 8-Channel Input 140 ARI 030 10
Redundant Power Supply Module Schneider Automation 8-Channel Input Module 140 ARI 030 10
Product Specifications
Main Specifications
  • Product Range: Modicon Quantum automation platform
  • Product Type: Analogue input module
Technical Details
  • Analogue Input Channels: 8
  • Input Type: Differential
  • Addressing Requirement: 9 input words
  • Analogue Input Resolution: 13 bits
  • Input Impedance: ≥ 10 MOhm
Temperature Probe Compatibility
  • Temperature probe -100...450 °C Pt 100, Pt 200, Pt 500, Pt 1000
  • Temperature probe -200...850 °C Pt 100, Pt 200, Pt 500, Pt 1000
  • Temperature probe -60...180 °C Ni 100, Ni 200, Ni 500, Ni 1000
  • Temperature probe 0.5 mA Ni 100, Ni 200, Ni 500, Ni 1000
  • Temperature probe 2.5 mA Pt 100, Pt 200, Ni 100, Ni 200
Performance Specifications
  • Absolute Accuracy Error: 0.1 °C
  • Linearity Error: ±0.01% full scale / ±0.5 °C
  • Accuracy Drift: ±0.5 °C at 25°C / ±0.9 °C at 0...60°C
  • Update Time: 1200 ms (3 wires) / 640 ms (2 wires/4 wires)
  • Fault Detection: Broken wire, Over tracking scale
Isolation & Safety
  • Isolation Channels to Bus: 2500 V DC for 60s / 1780 V AC 47...63 Hz for 60s
  • Isolation Between Channels: 300 Vrms AC
  • Bus Current Requirement: 200 mA
  • Power Dissipation: 1 W
LED Indicators
  • 1 LED Green: Bus communication present (Active)
  • 1 LED Red: External fault
  • 8 LEDs Green: Channel turned on
  • 8 LEDs Red: Channel fault
Physical Specifications
  • Module Format: Standard
  • Product Weight: 0.3 kg
Environmental Specifications
  • Operating Temperature: 0...60 °C
  • Storage Temperature: -40...85 °C
  • Relative Humidity: 95% without condensation
  • Operating Altitude: ≤ 5000 m
Certifications & Standards
  • Standards: CSA C22.2 No 142, UL 508
  • Certifications: CUL, FM Class 1 Division 2
  • ESD Resistance: 4 kV contact / 8 kV on air (IEC 801-2)
  • EMF Resistance: 10 V/m 80...1000 MHz (IEC 801-3)
  • Marking: CE
Sustainability
  • Green Premium Product: RoHS compliant (date code: YYWW)
  • Compliant since 0822 - Schneider Electric declaration of conformity
  • REACh: Reference not containing SVHC above threshold
  • Product Environmental Profile: Available
  • End of Life Manual: Available
  • Warranty Period: 18 months
Product Function
The Analog In 8 Channel Bipolar module accepts a mix of current and voltage inputs. Jumpers are required between the input and sense terminals for current inputs. The Quantum 140ARI03010 RT Input Module provides 8 channels of 2-wire, 3-wire, and 4-wire RTD inputs. Temperature measurement data is provided to the Quantum CPU.
Product Illustration
Schneider 140 ARI 030 10 Redundant Power Supply Module with 8-Channel Input for Modicon Quantum Automation 0
Module Components:
1. Model Number, Module Description, Color Code
2. LED Display
3. Fuse Cutouts
4. Field Wiring Terminal Strip
5. Removable Door
6. Customer Identification Label (Fold label and place it inside door)
NOTE: The field wiring terminal strip (Modicon #140 XTS 002 00) must be ordered separately.
Schneider 140 ARI 030 10 Redundant Power Supply Module with 8-Channel Input for Modicon Quantum Automation 1
External Wiring Recommendations
  • The user supplies the current and voltage sources
  • Use shielded signal cable; in noisy environments, twisted shielded cable is recommended
  • Shielded cables should be connected to the PLC's ground
  • A Shield Bar (STB XSP 3000 and STB XSP 3010/3020) should be used to connect shielded cable to ground
  • N/C = Not connected
  • Maximum wire size: 1-14 AWG or 2-16 AWG; minimum size: 20 AWG
WARNING: UNWIRED INPUTS CAUSE INVALID READINGS
When configured for voltage inputs (no jumper installed between INPUT(+) and ISENSE terminals), if a broken field wire occurs, readings will be non-zero and not predictable. The field wiring terminal strip must not be removed when the module is operating. Failure to follow these instructions can result in injury or equipment damage.
DANGER: HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Before accessing the fuses:
• Remove the power to the module (pre-actuators), and
• disconnect the terminal block.
• Always use a properly rated voltage sensing device at all line and load fuse clips to confirm power is off.
Failure to follow these instructions will result in death or serious injury.
Additional Product Information
The 140ARI03010 specifications include broken wire and short circuit detection. A quantum removable terminal strip (140XTS00200) is available and allows for easy maintenance. Quantum backplanes, such as the 10 slot 140XBP01000, are sold separately in 2, 3, 4, 6, 10, and 16 slot versions. Any quantum module can be used in any slot. A Quantum power supply is required in each rack, such as the 140CPS11420.
All Quantum I/O modules, including the 140ARI03010, are optically isolated from the bus, ensuring safe and trouble-free operation. The isolation allows modules to be hot swapped. Optionally, you can insert mechanical keys between the I/O module and the terminal strip to ensure that the field wiring and the module type are properly matched.
As an option, modules can be ordered with a conformal coating (designated as 140ARI03010C) which will protect the internal circuitry from corrosive gases such as Chlorine, Nitric Oxide, Hydrogen Sulfide, and Sulfur Dioxide.
Compatible Products
Manufacturer Product Series
Yasakawa Motor, Driver SG-
Mitsubishi Motor HC-, HA-
Westinghouse Modules 1C-, 5X-
Emerson VE-, KJ-
Honeywell TC-, TK-
GE Modules IC -
Fanuc motor A0-
Yokogawa transmitter EJA-
Similar Products
140ACI03000, 57
140ACI04000, 69
140ACO02000, 119
140ACO13000, 129
140AII33000, 517
140AII33010, 539
140AIO33000, 551
140AMM09000, 153
140ARI03010, 79
140ATI03000, 91
140AVI03000, 105
140AVO02000, 139
140DAI34000, 231
140DAI35300, 239
140DAI44000, 247
140DAI45300, 255
140DAI54000, 263
140DAI54300, 271
140DAI55300, 279
140DAI74000, 287
140DAI75300, 295
140DAM59000, 497
140DAO84000, 389
140DAO84010, 399
140DAO84210, 409
140DAO84220, 421
140DAO85300, 431
140DDI15310, 173
140DDI35300, 181
140DDI35310, 189
140DDI36400, 197
140DDI67300, 207
140DDI84100, 215
140DDI85300, 223
140DDM39000, 473
140DDM69000, 485
140DDO15310, 317
140DDO35300, 327
140DDO35301, 337
140DDO35310, 347
140DDO36400, 357
140DDO84300, 367
140DDO88500, 377
140DII33000, 573
140DIO33000, 563
140DRA84000, 441
140DRC83000, 449
140DSI35300, 303
140DVO85300, 457
140SAI94000S, 589
140SDI95300S, 601
140SDO95300S, 613
Contact Information
Contact Person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
Schneider 140 ARI 030 10 Redundant Power Supply Module with 8-Channel Input for Modicon Quantum Automation 2 Schneider 140 ARI 030 10 Redundant Power Supply Module with 8-Channel Input for Modicon Quantum Automation 3