|
|
Sales & Support 86-755-25020661
Request A Quote - Email Select LanguageEnglish
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Indonesian
Bengali
|
Product Details:
Payment & Shipping Terms:
|
Brand: | GE Fanuc | Model: | IC660BBS102 |
---|---|---|---|
Series: | Genius I/O | Product Type: | Output Block |
Number Of Outputs: | 8 | Number Of Output Groups: | 4 Groups Of 2 |
Voltage Type: | AC And DC | Nominal Voltage: | 115 Volts AC, 125 Volts DC |
Operating Temperature: | 32 To 140 Degrees Fahrenheit | Warranty: | 1 Year |
Highlight: | 5V DC Digital I O Module,PLC Isolated Relay Output Module,PCM Solid State Microcomputer Module |
The IC660BBS102 is a 115 VAC / 125 VDC Isolated I/O Block with eight circuits and Failed Switch Diagnostics by GE Fanuc. The IC660BBS102 is reported to continuously withstand 250 VAC/VDC between any group or ground or between any two groups. The block has a transient rating of 2000V peak for 10 seconds. Some configuarble features include AC/DC circuit voltage, defaults for output power-ups, CPU redundancy, a selectable input filter type ranging from 10mS to 100mS, capability for output pulse test, and module control for bus switching.
The block performs diagnostic tests that detect overload and no overload, I/O power loss on pairs of circuits, over-temperature, and open wire for tristate inputs. As long as terminals 5 and 6 are recieving power, the isolated I/O block should operate. Temperatures in excess of 100°C trigger an OVERTEMPERATURE message and turns off the circuit to protect the internal electronics of the unit. The short circuit level sensor at the switching device protects the output circuits. Outputs are configured to report No-Load conditions for a new block. Genius I/O blocks are considered "open equipment" and must be installed in a protective enclosure, clean and free of airborne contaminants and with adequate cooling airflow. The block can be mounted right side up, or upside down. Leave at least 2 inches of space between blocks. The block’s mounting screws must not be used as the only means of grounding the block.
The IC660BBS102 block is fully compatible with handheld monitor IC660HHM501 and any GE Fanuc bus controller. Blocks numbered IC660CBS100, 1C660BBS100, and IC660BBS101 are backward compatible with previous versions of this Genius I/O block. Terminal assembly model IC66*TSS100E is not compatible with earlier versions of the block. During field wiring, all terminal blocks can accommodate one AWG #12 or two AWG #14 wires. Terminals labeled 1 to 4 can accommodate ring terminals measuring up to 0.27 inches. Recommended torque for all terminals is 6 inches/lb.
Rated Voltage: | 115 VAC / 125 VDC |
# of Points: | 8 |
Input Voltage Range: | 93 - 132 VAC |
Output Voltage Range: | 105 - 132 VDC |
Load Current per Point: | 2.0 Amps |
Points per Common | Four Groups of 2 |
Block Type: 115VAC / 125VDCIsolatedI / OBlock: Terminal Assembly Only: ElectronicsAssemblyOnly: 115VAC / 125VDCIsolatedI / OBlock,NoFailed Switch: Terminal Assembly Only: ElectronicsAssemblyOnly: |
8 ckt isolated input / output in 4 isolated pairs IC660BBS102, replaces IC660BBS100 IC660TSS100 IC660EBS100 IC660BBS103, replaces IC660BBS101 IC660TSS100 IC660EBS101 |
Size (height x width x depth): Weight: LED’s (I/O Block): LED’s (each circuit): Block to Block Isolation: HeatDissipation: |
8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” x (10.00cm) 4 lbs. (1.8 kg) Unit OK, I / OEnabled On logic side of switch 1500 V 16.8W max. with 8 inputs on, 45.6W max. with 8 outputs at 2 amps |
Operating Temperature Storage Temperature Humidity Vibration |
–0 to +60C (32 to +140F) –40 C (–40 to +212F) 5% to 95% (non–condensing) 5–10 Hz 0.2” (5.08mm) displacement, 10–200 Hz at 1G |
Required control power (block only): Operating voltage (four sources): Frequency/ripple: Power supply dropout time: |
8 Wattsmaximum |
93–132 VAC105–132 VDC 47–63 Hz10% max. ripple 1 cycle10mS |
|
Input Characteristics: Non–tristate input, OFF state: Minimum voltage across input device (IN to H) Maximum leakage through input device Non–tristate input, ON state: Maximum voltage across input device (IN to H) Maximumswitchcurrent threshold Tristate input: OFF, acceptable voltage across input device (IN to H) ON, maximum voltage across input device (IN to H) Input load network: Resistor to N Capacitor to H: for blocks BBS100 and BBS101 Capacitor to H: for blocks BBS102 and BBS103 Input processing time (typical) Selectable input filter times Inputdiagnostics |
For ACFor DC 60 VRMS70 VDC 1 mA2 mA 20 VRMS35 VDC 6 mA RMS5 mA 16 VRMS–40 VRMS16 VDC–35 VDC 4 VRMS3.5 VDC 13K ohms13K ohms .22 ïf.22 ïf .1 ïf.1 ïf 2mS + filter0.8mS + filter |
10 to 100mS in 10mS increments Open Wire, Overtemperature, Loss of I / O Power, Failed Switch |
|
OutputCharacteristics: Output current (steady state) Maximum inrush current Output Leakage: Current at 0 volt output: for blocks BBS102 and 103 Current at 0 volt output: for blocks BBS100 and 101 Voltage at open output: for blocks BBS102 and 103 Voltage at open output: for blocks BBS100 and 101 Output switch (OFF to ON / ON to OFF) Rated switching frequency at maximum inrush Turn–on delay (maximum) Voltage drop (at 2 amps) Voltage drop (at 20 amps inrush) Minimum load (No Load disabled) Resistive: for blocks BBS102 and BBS103 Resistive: for blocks BBS100 and BBS101 Inductive: for blocks BBS102 and BBS103 Inductive: for blocks BBS100 and BBS101 No Load enabled threshold Maximum block output current Fusing Output diagnostics |
For ACFor DC 2 amps2 amps resistive 9 (1 amp inductive*) 25 amps (2 cycles)25 amps (10mS peak) 7 mA2 mA 13mA2 mA 65 volts40 volts 95 volts40 volts Zerocrossing––– Once per secondOnce per second 0.5 Hz + 1mS1mS 2.5 volts2.5 volts 10 volts10 volts 25 mA10 mA 30 mA10 mA 40 mA10 mA 100mA10 mA 50 mA50 mA |
15 amps at 35 C, 7.5 amps at 60C Internal electronic short circuit trip. 100ms(AC), 10ms (DC) long time trip Short Circuit, Overload, No Load, Overtemp., Loss of I / O Power.Also, for blocks BBS100 and BBS 102 only: Failed Switch |
Contact Person: Mayne
Tel: +86 13170829968