Product Details:
Payment & Shipping Terms:
|
Brand: | Schneider | Model: | 140ACI04000 |
---|---|---|---|
Palce Of Origin: | FR | Type: | Processor/Controller |
Addressing Requirement: | 17 Input Words | Module Format: | Standard |
Analogue Input Number: | 16 | Weight: | 0.3KG |
Highlight: | plc power supply module,diode redundancy module |
Redundant Power Supply Module Schneider TSX Quantum PLC 140-ACI-040-00 140ACI04000
Alternate Part Number:
Main
range of product
Modicon Quantum automation platform
product or component type Analogue input module
type of filter Single pole low pass - 3 dB at 34 Hz +/- 25 %
Complementary
analogue input number 16
input type Differential
addressing requirement 17 input words
analogue input resolution
0...16000 counts 4...20 mA
0...20000 counts 0...20 mA
0...25000 counts 0...25 mA
0...4095 counts 4...20 mA
absolute maximum input 30 mA
input impedance 250 Ohm
absolute accuracy error
+/- 0.125 % of full scale
linearity error
+/- 12 µA max 4...20 mA
+/- 6 µA max 0...20 mA
+/- 6 µA max 0...25 mA
+/- 6 µA max 4...20 mA
accuracy drift according to temperature
+/- 0.0025 % of full scale/°C
<= 0.0050 % of full scale /°C
common mode rejection > - 90 dB 60 Hz
isolation between channels and bus 1780 V AC for 60 s
update time 15 ms 2 wires/4 wires
fault type Broken wire 4...20 mA
marking CE
local signalling
1 LED green bus communication is present (Active)
1 LED red external fault
16 LEDs green channel is turned on
16 LEDs red channel fault
bus current requirement 360 mA
power dissipation in W 5 W
module format Standard
product weight 0.66 lb(US) (0.3 kg)
Environment
standards CSA C22.2 No 142
UL 508
product certifications CUL
FM Class 1 Division 2
resistance to electrostatic discharge
4 kV contact conforming to IEC 801-2
8 kV on air conforming to IEC 801-2
resistance to electromagnetic fields
9.14 V/yd (10 V/m) 80...1000 MHz conforming to IEC 801-3
ambient air temperature for operation 32...140 °F (0...60 °C)
ambient air temperature for storage -40...185 °F (-40...85 °C)
relative humidity 95 % without condensation
operating altitude <= 16404.2 ft (5000 m)
Ordering and shipping details
Category
18155 - QUANTUM I/O & POWER SUPPLIES
Discount Schedule PC21 GTIN
00785901334019
Nbr. of units in pkg. 1
Package weight(Lbs) 0.98999999999999999
Returnability Y
Country of origin FR
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Similar Products
140DDI67300 | 140DDI67300C | 140DDI84100 |
140DDI84100C | 140DDI85300 | 140DDI85300C |
140DDM39000 | 140DDM39000C | 140DDM69000 |
140DDM69000C | 140DDO15310 | 140DDO15310C |
140DDO35300 | 140DDO35300C | 140DDO35310 |
140DDO35310C | 140DDO84300 | 140DDO84300C |
140DDO88500 | 140DDO88500C | 140DII33000 |
140DIO33000 | 140DRA84000 | 140DRA84000C |
140DRC83000 | 140DRC83000C | 140EDK21100 |
The Modicon Quantum 140ACI04000 analog input module provides 16 channels. Each channel is individually configurable for a 0…25 mA, 0…20mA, or 4…20mA signal.
The 140ACI04000 module has broken wire detection in the 4…20mA current mode.
A Quantum removable terminal strip, part number 140XTS00200, is used to allow for easy maintenance. The terminal strip is connected with two screws and can easily be used with any of the Input-Output modules in the Quantum series.
Related Documents
Title of Documentation Reference Number
Quantum Discrete and Analog I/O Reference Manual Part of this package
Quantum Experts and Communication Reference Manual Part of this package
Grounding and Electromagnetic Compatibility of PLC Systems User Manual
Part of this package
Quantum and Premium Communication Architecture Reference Manual
UNYUSE10410V20E
Quantum Hot Standby User Manual UNYUSE10710V20E
Modicon Remote I/O Cable System Planning and Installation Guide 890USE10100
Modbus Plus Planning and Installation Guide 890USE10000
140 EIA 921 00 Quantum AS-i-Bus Interface Module User Manual UNYUSE10410V20E
Quantum TCPIP/IP Configuration User Manual UNYUSE10410V20E
140 NOE 771 xx Quantum Ethernet-Modules User Manual UNYUSE10410V20E
140 ESI 062 10 Quantum ASCII Interface Module User Manual UNYUSE10410V20E
140 ERT 854 10 Quantum Time Stamp Module User Manual UNYUSE10620V20E
140 DCF 077 00 Quantum Clock Module User Manual UNYUSE10910V20E
140 HLI 340 00 Quantum High Speed I/O Module with Interrrupt
Function User Manual
UNYUSE10630V20E
140 EHC 105 00 High Speed Counter Module User Manual UNYUSE10510V20E
140 MSB 101 00 / 140 MSC 101 00 Quantum Single Axis Motion
Module User Manual
UNYUSE10520V20E
140 NOA 622 00 Quantum INTERBUS-Master Module User Manual UNYUSE10410V20E
140 CRP 811 00 Quantum Profibus DP Module User Manual UNYUSE10410V20E
Product Related Warnings
Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to ensure compliance with documented system data, only the manufacturer should perform repairs to components. When controllers are used for applications with technical safety requirements, please follow the relevant instructions. Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this product related warning can result in injury or equipment damage.
Purpose
This chapter provides information on the three different modes Unity Pro allows to address the I/O data from a Quantum I/O module: z Flat Addressing z Topological Addressing z IODDT Addressing While Flat Addressing and Topological Addressing are available for all Quantum I/ O modules, IODDTs are only provided for modules which deliver information additional to the I/O values (e.g. errors or warnings). Also provided is information about the I/O modules status byte and about bit order.
Contact Person: Harper
Tel: 86-13170829968