Home ProductsRedundant Power Supply Module

Electric Modicon Redundancy Diode Module I / O Type 10 Free Slot 140XBP01000

Superb delivery a great product, perfect communication as well !! A++++

—— Carlos

Great deal. Fast shipping and good service.Recommended !!!!!!!!!

—— Gita

I'm Online Chat Now

Electric Modicon Redundancy Diode Module I / O Type 10 Free Slot 140XBP01000

Large Image :  Electric Modicon Redundancy Diode Module I / O Type 10 Free Slot 140XBP01000

Product Details:

Place of Origin: FR
Brand Name: Schneider
Model Number: 140XBP01000

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, Western Union
Supply Ability: 100
Detailed Product Description
Brand: Schneider Model: 140XBP01000
Palce Of Origin: FR Type: I/O Modules
Marking: CE Module Format: Standard
Free Slot: 10 Weight: 1 Kg
High Light:

plc power supply module

,

diode redundancy module

Schneider Electric Modicon140XBP01000 NEW Excellent Modicon 10 Slot Backplane
 

 

 

Specifications

 
Main
Range of product Modicon Quantum automation platform
Product or component type Rack backplane
Product specific application
For distributed I/O modules
For local I/O modules
For remote I/O modules
Complementary
Free slots 10
Mounting support Mounting plate
Fixing mode By screw
Product weight 1 kg
Offer Sustainability
Sustainable offer status Green Premium product
RoHS Compliant - since 0923 - Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Product environmental profile Available Download Product Environmental
Product end of life instructions Need no specific recycling operations
Contractual warranty
Period 18 months
 
 
 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
 
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
 
 
 
 
 
Similar Products
140XTS01209
140XTS01212
140XTS10206
140XTS10215
140XTS33200
141MMS42501
141MMS53502
490NAA27101
490NAA27102
490NAA27103
490NAA27104
490NAA27106
490NAC72100
490NAD91103
490NAD91104
490NAD91105
490NAE91100
490NOC00005
490NOR00005
490NOT00005
490NRP25300
490NRP25400
490NRP95400
490NTC00005
490NTC00005U
490NTC00015
490NTC00015U
490NTC00040
490NTC00040U
490NTC00080
490NTC00080U
490NTRJ11
490NTW00002
490NTW00002U
490NTW00005
490NTW00005U
490NTW00012
490NTW00012U
490NTW00040
490NTW00040U
490NTW00080
 
 
 
The following diagram shows the register of the second input word. Bit 15 set to 1 means that there is an overload problem on channel 1, bit 14 set to 1 means that there is an overload problem on channel 2, and so on
 
 
NOTE: In case of activation of the overload bit, the corresponding output is automatically switched to the OFF state by the module (disjunction) and maintained
OFF during at least 10 seconds. To recover the control of the output, it is necessary to set by application the overloaded output command of the module to the OFF state.
 
 
Addressing
The following information describes how the data exchanged between the
140 SDO 953 00S module and the processor module are mapped.
Except for the health word, the data described here are transferred to and from the
140 SDO 953 00S module using the Quantum global backplane communication
access mechanism which is common to all Quantum modules.
NOTE: The words "input" and "output" used here are defined with respect to the
processor module.
11 words are necessary for this module:
? 4 words dedicated to output data
? 1 dedicated to channel values
? 3 words used by the module (exchange number, CRC)
? 6 words dedicated to inputs data:
? 1 dedicated to energized/de-energized channel detection
? 1 dedicated to overload errors
? 1 dedicated to unsafe channel errors
? 1 dedicated to process power supply status, malfunction from the host (and
exchange number which is used by the module)
? 2 words used by the module (CRC)
? 1 health word (this word is accessible by the processor module only)
 
 
 
 
The following figure shows the wiring diagram for the 140XBP01000 module
 
power supply: 24 VDC
fuse: 10 A max (determined by the module load current), fast blow
pre-act: pre-actuator
NOTE: There is only one group of 16 outputs. All common 24 V are internally
connected and all common 0V are also internally connected. For safety applications,
it is recommended to connect at least 2 ground lines (common 0V) to the field wiring