Shenzhen Wisdomlong Technology CO.,LTD

 

Work hard and best service for you!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsRedundant Power Supply Module

2 Group Channels Redundancy Diode Module 115 Discrete Input Voltage 140DAI54300

Superb delivery a great product, perfect communication as well !! A++++

—— Carlos

Great deal. Fast shipping and good service.Recommended !!!!!!!!!

—— Gita

I'm Online Chat Now

2 Group Channels Redundancy Diode Module 115 Discrete Input Voltage 140DAI54300

Large Image :  2 Group Channels Redundancy Diode Module 115 Discrete Input Voltage 140DAI54300

Product Details:

Place of Origin: FR
Brand Name: Schneider
Model Number: 140DAI54300

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, Western Union
Supply Ability: 100
Detailed Product Description
Brand: Schneider Model: 140DAI54300
Palce Of Origin: FR Type: Redundant
Discrete Input Voltage: 115 Discrete Input Number: 16
Group Of Channels: 2
Highlight:

plc power supply module

,

diode redundancy module

Redundant Power Supply Module SCHNEIDER TSX QUANTUM MODICON 140DAI54300​
 

 
 
 
 
 
Specifications

Manufacturer: Modicon Quantum
Series: Power Supplies
Weight: 2 lb
Power supply type: Redundant
Input voltage: 230 V AC 170...276 V
  115 V AC 93...138 V 47...63 Hz
Input current: 1100 mA 115 V
  600 mA 230 V
Inrush current: 19 A 230 V
  38 A 115 V
Rated power in VA: 130 VA
Associated fuse rating: 2 A slow-blow
Harmonic distortion: <= 10 % of fundamental rms value
Output voltage: 5.1 V DC
Power supply output current: 8 A 60 °C redundant
Output overvoltage protection: Internal
Output overload protection: Internal
Power dissipation: 6 + (1.5 x Iout) where Iout is in A
Local signalling: 1 LED green power (PWR OK)
Marking: CE
Module format: Standard

 

 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
 
 
Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279
 
 
 
 

Similar Products

140ACO13000 140AII33000 140AMM09000 140ATI03000
140ARI03000 140ARI03010 140AVI03000 140AVO02000
140CFA04000 140CHS11000 140CHS32000 140CHS41010
140CPS11100 140CPS11410 140CPS12400 140CPS21100
140CPS21400 140CPU11302 140CPU11303 140CPU21304
140CPU21304C 140CPU41100 140CPU42401 140CPU42402
140CPU43412 140CPU43412A 140CPU53414 140CPU53414A
140CRA21110 140CRA93100 140CRA93101 140CRA93200
140CRP81100 140CRP93100 140CRP93200 140DAI35300
140DAI54000 140DAI54300 140DAI55300 140DAO84000

 

 

Description: Input Module | TSX Quantum I/O
Discrete Input Voltage: 115 V AC
Network Frequency Limits: 47...63 Hz
Range of Product: Modicon Quantum automation platform
Discrete Input Number: 16
Group of Channels: 2
Addressing Requirement: 1 Input Word

 

 

 

The Modicon TSX Quantum Automation Series supports a full range of discrete I/O modules designed to interface with a wide variety of field devices. All modules meet internationally accepted IEC electrical standards that ensure reliability in harsh operating environments. For even better protection and extended life in extremely harsh environments, you can have your modules conformally coated.

 

 

Fully software-configurable

All Quantum I/O modules can be completely configured using Concept or Modsoft. The ability to specify an I/O address for each module in software makes it easy to add or change modules in your configuration without physically changing the application program.

 

 

 

Defining the failure mode of an output module

Quantum gives you the ability to predefine how a discrete output point will respond if for any reason the module stops beingserviced. You can configure the module in software so that the outputs:
i Turn off
i Go to a predefined safe state
i Hold the last value they received before the watchdog timer expired
Failure modes can be defined on a point-by-point basis. In the event of a complete module failure, the fail state settingsyou have specified can be sent to the replacement module.

 

 

Mechanical keying for added security

Optionally, you can insert mechanical keys between the I/O module and the terminal strip to ensure that the field wiring and the module type are properly matched. Keying codes are unique for each module type. You can also implement mechanical keying for unique slot locations so that a rack full of similar modules with similar keying codes will not be incorrectly connected. Keys are shipped with the I/O modules. They do not need to be ordered separately.

 

 

I/O connectors

Each I/O module requires an I/O connector (P/N 140 XTS 002 00), which can be ordered separately. The same connector can be used with all modules.

 

 

 

Contact Details
Shenzhen Wisdomlong Technology CO.,LTD

Contact Person: Harper

Tel: 86-13170829968

Send your inquiry directly to us Message not be empty!