Product Details:
Payment & Shipping Terms:
|
Brand: | Norgren | Model: | SXE9573-A71-00K |
---|---|---|---|
Origion: | English | Flow: | 1230.00 L/min |
Operation: | 5/2 | Packing: | Carton |
Highlight: | ac servo motor,electric servo motor |
ISO Star Valve - Solenoid Norgren SXE9573-A71-00K Flow: 1230.00 l/min Operation: 5/2
Flow: | 1230.00 l/min |
---|---|
ISO size: | ISO #1 |
Operation: | 5/2 |
Actuation: | Sol/Spring |
Standard: | ISO 5599-1;VDMA 24 345 |
Series: | ISO Star |
Technical Details
Medium: | Compressed air |
---|---|
Operation: | 5/2 |
Actuation: | Sol/Spring |
Operating pressure: | 1 ... 10 bar |
Operating temperature: | -15 ... 80 °C |
ISO size: | ISO #1 |
Pilot: | Internal |
Manual Override: | Locking |
Protection class: | IP65 |
Standard: | ISO 5599-1;VDMA 24 345 |
Flow: | 1230.00 l/min |
Material - Body: | Diecast aluminium |
Material - Nuts & screws: | Zinc plated steel |
Material - Seals: | Nitrile rubber;Heat resistant seals |
Material - Spool and sleeve: | Anodised aluminium with special coating |
Series: |
ISO Star |
1 Intended usage Please review all ATEX data and notes in this operating manual to eliminate any risks which would jeopardize the safe function of the complete configured valves with valve solenoids. Any use beyond the permissible limits, or the failure to comply with the instructions of this manual, will cause the user to be liable for damages. In case of non-permissible intrusions or modifications of the valve, as well as failing to comply with the instructions of this manual, the claim for guarantee expires and our liability is excluded. The valves must be used only with noncombustible mediums which do not corrode, chemically or mechanically, the materials used. Use only mediums approved by IMI Norgren.
2 Operating manual 2.1 General conditions • The valves mentioned in this manual must be used with its permissible valve solenoids (armature assembly and coil) and these valve solenoids must be used with the IMI Norgren valves. If the valve solenoid used is from another manufacturer, or if our valve solenoids are used on another manufacturer’s valve, IMI Norgren assumes no liability. Moreover the Ex approval as well as the claim of guarantee expires for items of equipment and accessories. • Before installation, the specifications of the device identification are to be compared with the intended operating conditions to ensure proper usage. • Take measures to avoid unintentional or improper activation. • Consider in case of pressurised systems that lines, valves and other components should not be removed. • ATTENTION: There is some risk of injury! The surface of coils could become very warm in continuous operation. • Leak and strength tests on open and closed valves are admissible until max. 1.5 times the max. operating pressure. It is not allowed to operate the valve during these tests. • Do not use inlet air of an area with potentially explosive atmosphere. • In case of applications with vacuum, please consider that no ambient gases or dust could be leak into the valve so that no potentially explosive situation inside of the valve or other components can arise. • Never use the valve solenoid as well as the complete valve as lever arm or a step for climbing.