Payment & Shipping Terms:
|
Brand: | Yasakawa | Model: | SGD-A3AP |
---|---|---|---|
Palce Of Origin: | Japan | Type: | Servopack |
Output AMPS: | 0.42 | Input Volatge: | 200-230v |
Input Frequency: | 50/60hz | Input PH: | 1 |
Highlight: | electric servo drive,ac servo drive |
YASKAWA Input 1.3 AMPS Servo Drives SERVOPACK 50/60hz With One Phase SGD-A3AP
Quick Details
Brand Name:Yaskawa
Model Number:SGD-A3AP
Input Voltage:200-230V
Input Frequency:50/60HZ
Input PH : 1
Input AMPS:1.3
Series : Sigma 2 (Σ-II Series)
Output Power : 30W
Output Voltage: 0-200V
Output AMPS:0.42
Temperture: 0-55℃
Place of Origin:Japan
Efficiency:IE 1
SGD-01AN+SGM-01A3NT14 |
SGD-01AHY130 |
SGD-01AS |
SGD-01BH |
SGD-01BP |
SGD-02AH |
SGD-02AHY500 |
SGD-02AN |
SGD-02ANY6 |
SGD-02AP |
SGD-02AS |
SGD-02BH |
SGD-02BP |
SGD-02BS+SGM-02B312 |
SGD-02BS+SGM-02B314 |
SGD-04AN |
SGD-04AN+SGM-04A3NT12 |
SGD-04AP |
SGD-04APY61 |
SGD-04AS |
SGD-04ASY52 |
SGD-04ASY53 |
SGD-08AH |
SGD-08AN |
SGD-08AP |
SGD-08APY61 |
SGD-08ASY25 |
Electrical Shock Hazard
Do not operate equipment with covers removed. Failure to comply could result in death or serious injury. The diagrams in this section may show drives without covers or safety shields to show details. Be sure to reinstall covers or shields before operating the drives and run the drives according to the instructions described in this manual. Always ground the motor-side grounding terminal. Improper equipment grounding could result in death or serious injury by contacting the motor case.
Do not perform work on the drive while wearing loose clothing, jewelry or without eye protection. Failure to comply could result in death or serious injury. Remove all metal objects such as watches and rings, secure loose clothing, and wear eye protection before beginning work on the drive.
Do not remove covers or touch circuit boards while the power is on. Failure to comply could result in death or serious injury.
Do not allow unqualified personnel to perform work on the drive. Failure to comply could result in death or serious injury. Installation, maintenance, inspection, and servicing must be performed only by authorized personnel familiar with installation, adjustment, and maintenance of AC drives.
Do not touch any terminals before the capacitors have fully discharged. Failure to comply could result in death or serious injury. Before wiring terminals, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least one minute after all indicators are off and measure the DC bus voltage level to confirm safe level. Fire Hazard Tighten all terminal screws to the specified tightening torque. Loose electrical connections could result in death or serious injury by fire due to overheating of electrical connections. Do not use improper combustible materials. Failure to comply could result in death or serious injury by fire. Attach the drive to metal or other noncombustible material
.Do not use an improper voltage source. Failure to comply could result in death or serious injury by fire. Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power
• Never touch any rotating motor parts while the motor is running.Failure to observe this warning may result in injury.
• Before starting operation with a machine connected, make sure that anemergency stop can be applied at any time.Failure to observe this warning may result in injury or damage to the product.
• Never touch the inside of the SERVOPACKs.Failure to observe this warning may result in electric shock.
• Do not remove the cover of the power supply terminals while the power isON.Failure to observe this warning may result in electric shock
.• After the power is turned OFF or after a voltage resistance test, do nottouch terminals while the CHARGE lamp is ON.Residual voltage may cause electric shock.
Managed by a team of highly dedicated and immensely talented technicians, we have surpassed our counterparts by maintaining client-centric approach. In order to continue the same tradition, we have been offering quality bound services for more than 20 years.
Our range includes CNC Machine Card Servicing, Drive Repairs, VFD Repair, Servo Drive Repairs, Power plant equipment ,Medical device , CNC Boards Repair, Servo Controllers Repairs, Servo Motor Repair, Encoder Repair, DC Drive Repair, PLC Repairs, Spindle Drive Repairs, Industrial Power Supply Repairs, Robotic Card - Controller Repair, Electronic PCBs Repair & Reconditioning, Telecommunication Equipment Repair, Processor Boards Repairs, Industrial Monitor Repair, Industrial Motor Repair, Servo Motor and CNC Machine Control Cards Repair.
We maintain a large inventory of electronic components and ICs. Our technicians thoroughly analyze and diagnose the reason behind the failure or damage of the appliances. The components repaired by us are twice as good as the damaged products in terms of their quality. Our repaired products carry a default 30 days warranty unless otherwise stated. We ensure minimal turnaround time for rendering our services.
complete solutions for repairing,testing, and maintenance of high value electronic Printed Circuit Boards (PCBs) & modules and solving obsolescence issues or re-manufacturing obsolete circuits.
We specialize in industrial electronics repair in India and Abroad
OTHER SUPERIOR PRODUCTS
Contact Person: Harper
Tel: 86-13170829968