AJ55TB2-16T Redundant Power Supply Module Mitsubishi Universal Model
Product Details:
| Place of Origin: | Japan |
| Brand Name: | MITSUBISHI |
| Certification: | CE |
| Model Number: | AJ55TB2-16T |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 |
|---|---|
| Price: | Contact |
| Packaging Details: | new and original |
| Delivery Time: | 5-7 days |
| Payment Terms: | T/T, Western Union,paypal |
| Supply Ability: | 100 |
|
Detail Information |
|||
| Brand: | MITSUBISHI | Modenl Number: | AJ55TB2-16T |
|---|---|---|---|
| Country Of Origin: | Japan | Program Capacity: | 8 K Steps |
| Basic Operation Processing Speed (LD Instruction): | 0.12 μs | Input: | 100 To 240 V AC |
| Output: | 5 V DC/3 A | Type: | Redundant Power Supply Module |
| Highlight: | plc power supply module,diode redundancy module |
||
Product Description
AJ55TB2-16T Redundant Power Supply Module Mitsubishi Universal model
AJ55TB2-16T Overview
The AJ55TB2-16T is a 16-point transistor output module (sink-type/NPN) designed by Mitsubishi Electric for its MELSEC-I/O communication system. It functions as a remote I/O station within industrial automation networks, enabling high-speed control of actuators (e.g., solenoids, relays) by converting digital signals from a PLC into DC outputs. Designed for reliability and noise immunity, it simplifies wiring in distributed control systems and is widely used in manufacturing, packaging machinery, and process automation.
AJ55TB2-16T Key Features
- 1.
High Reliability and Fault Tolerance
- •
Utilizes Mitsubishi's MELSEC-I/O bus topology, ensuring that the failure of one remote I/O group does not disrupt communication in other modules, enhancing system stability
.
- •
- 2.
Fast Response and Precision
- •
Transistor-based sink-type outputs enable rapid switching, with response times optimized for high-speed automation tasks (e.g., conveyor control, robotic operations).
- •
- 3.
Robust Isolation and Noise Resistance
- •
Features photocoupler isolation between communication, power, and output circuits, protecting against electrical noise and voltage surges in industrial environments.
- •
- 4.
Compact and Scalable Design
- •
Occupies minimal space in control panels and supports seamless integration with CC-Link or MELSEC networks, allowing flexible system expansion.
- •
- 5.
Efficient Wiring
- •
Uses terminal block connections (M3 screws) for secure and straightforward wiring, reducing installation time and maintenance efforts.
- •
AJ55TB2-16T Material and Applications
- •
Material: Constructed with industrial-grade plastics and metal components, providing EMI shielding and mechanical durability. The internal circuitry includes photocouplers and transistor arrays for isolation and precision performance.
- •
Primary Applications:
- •
Factory Automation: Control of actuators in automotive assembly lines, packaging machines, and robotic systems.
- •
Energy Management: Switching operations in power distribution units.
- •
Process Control: Output signaling for chemical and pharmaceutical production equipment.
- •
AJ55TB2-16T Technical Parameters
Data synthesized from Mitsubishi's MELSEC-I/O module specifications and industry standards.
Transistor output: 16 points.
DC12/24V.
Response AJ55TB2-16T time: 2ms.
16 points per common.
Sink AJ55TB2-16T type.
40-point terminal block
Transistor MITSUBISHI AJ55TB2-16T output: 8 points.
DC12/24V.
Response time: 2ms.
8 points per common.
Sink MITSUBISHI AJ55TB2-16T type.
24-point terminal block
Model: AJ55TB2-4R
Contact MITSUBISHI AJ55TB2-16T output: 4 points.
DC24V/AC240V.
Point 2A / 1
8A / 1 Common.
Response time: 12ms.
4 points per common.
16-point terminal block
Model: AJ55TB2-8R
Contact output: 8 points.
DC24V/AC240V.
Point 2A / 1.
8A / 1 Common.
Response time: 12ms.
8 points per common.
24-point terminal block
Model: AJ55TB2-4T
Transistor output: 4 points.
DC12/24V.
Response time: 2ms.
4 points per common..
Sink AJ55TB2-16T type.
16-point terminal block
|
Attribute |
Value |
|---|---|
|
For Use With |
MELSEC Q Series |
|
Number of I/O |
2048 |
|
Manufacturer Series |
MELSEC Q |
|
Input Type |
Analogue, Digital |
|
Voltage Category |
5 V dc |
|
Output Type |
Analogue, Digital |
|
Communication Port Type |
RS232C |
|
Program Capacity |
32 kB |
|
Programming Interface |
Computer, Operating Panel |
|
Length |
89.3mm |
|
Maximum Inputs/Outputs |
8192 |
|
Number of Communication Ports |
1 |
|
Width |
27.4mm |
|
Maximum Operating Temperature |
+55°C |
|
Dimensions |
89.3 x 27.4 x 98 mm |
|
Depth |
98mm |
|
Battery Backup |
Yes |
|
Minimum Operating Temperature |
0°C |
|
Mounting Type |
DIN Rail |
|
Memory |
94 kB |
Model: QJ71FL71-B2-F01
Ver.2.00.
10BASE2
Mitsubishi QJ71FL71-B2-F01
Model: QJ71FL71-B5-F01
Ver.2.00.
10BASE5
Model: MITSUBISHI QJ71FL71-B2-F01 QJ71FL71-B5
Ver.1.00.
10BAASE5
Model: QJ71FL71-B2-F01 QJ71FL71-B2
Ver.1.00.
10BASE2
Similer item we can supply:
|
Q01CPU |
Q02(H)CPU |
Q06HCPU |
|
Q12HCPU |
Q25HCPU |
Q02PHCPU |
|
Q06PHCPU |
Q12PHCPU |
Q25PHCPU |
|
Q00UCPU |
Q01UCPU |
Q02UCPU |
|
Q03UDVCPU |
Q03UD(E)CPU |
Q04UDVCPU |
|
Q04UD(E)HCPU |
Q06UDVCPU |
Q06UD(E)HCPU |
|
Q10UD(E)HCPU |
Q13UDVCPU |
Q13UD(E)HCPU |
|
Q20UD(E)HCPU |
Q26UDVCPU |
Q26UD(E)HCPU |
|
Q50UDEHCPU |
Q50UDEHCPU |
Q50UDEHCPU |
|
Q01UCPU |
Q02CPU |
Q02CPU-A |
Our advantage Products:
【Honeywell】Module DCS / PLC
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
(Modicon,SMC,SICK,NORGREN,Siemens etc.)
![]()