Brand: | Yasakawa | Model: | SGMG-44A2BBC |
---|---|---|---|
Palce Of Origin: | Japan | Type: | Servo Motor |
Power: | 4400W | Current: | 32.8A |
Voltage: | 200V | R/min: | 1500 |
Highlight: | ewing machine servo motor,ac servo motor |
New Yaskawa AC Servo Motor 32.8A 1500RMP SGMG-44A2BBC Industrial Servo Motor
Specifications
Current: 32.8A
Volatge: 200V
Power :4400W
Max speed: 1500rpm
Encoder: 17bit Absolute encoder
Load Inertia JL kg¡m2¢ 10−4: 0.026
Shaft: straight without key
OTHER SUPERIOR PRODUCTS
SGMG-20A2AAB |
SGMG-20A2AB |
SGMG-20A2ABC |
SGMG-20A2ABS |
SGMG-20A2BB |
SGMG-20A2BBB |
SGMG-20ASA |
SGMG-20AWA |
SGMG-30A2A |
SGMG-30A2AAB |
SGMG-30A2AB |
SGMG-30A2ABC |
SGMG-30A2ABS |
SGMG-30AWA |
SGMG-30V2AB |
SGMG-40V2AB |
SGMG-44A2AAB |
SGMG-44A2AB |
SGMG-44A2ABC |
SGMG-44ASAAB |
SGMG-44V2AB |
SGMG-55A2A |
SGMG-55A2AAB |
SGMG-55A2AB |
SGMG-55A2ABC |
SGMG-60A2BBB |
SGMG-60A2BBC |
SGMG-75A2AAB |
SGMG-75A2AB |
SGMG-75A2ABC |
MOTOR 1.1 Verify motor nameplate data meets the application – hp, voltage, phase, and Hertz.
1.2 Check that the motor shaft rotates freely by hand on the second of two complete rotations. (On large motors, this usually requires a motor coupling with a cheater handle welded to it.)
1.3 Check that the motor lead assembly is not damaged.
1.4 Measure insulation resistance to ground at 500 volts – BEFORE SUBMERGED. It should be a minimum of 200 megohms or 200,000,000 ohms.
1.5 Measure insulation resistance to ground at 500 volts – AFTER SUBMERGED. It should be a minimum of 0.5 megohms or 500,000 ohms.
1.6 Verify the system is operating within the ±10% of nameplate voltage requirement.
1.7 Verify the system will not ever operate in excess of the maximum amps indicated on the nameplate. 1.8 Verify the system is operating at 5% or less current unbalance.
Notice:
• If current unbalance exceeds 5%, the maximum operating amps must be derated to the nameplate Full Load Amps.
• Warning - System current unbalance can not exceed 10% without causing heating and mechanical wear issues.
• The submersible motor amperage % unbalance is typically 6x greater than its voltage % unbalance.
• Thus, 0.8% voltage unbalance = greater than 5% current unbalance, and 1.7% voltage unbalance = greater than 10% current unbalance.