Shenzhen Wisdomlong Technology CO.,LTD

 

Work hard and best service for you!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsRedundant Power Supply Module

Schneider Electric Series Modicon Quantum 140AMM09000 Modicon Quantum Analog I/O 4ch/2ch Module PV:00

Superb delivery a great product, perfect communication as well !! A++++

—— Carlos

Great deal. Fast shipping and good service.Recommended !!!!!!!!!

—— Gita

I'm Online Chat Now

Schneider Electric Series Modicon Quantum 140AMM09000 Modicon Quantum Analog I/O 4ch/2ch Module PV:00

Large Image :  Schneider Electric Series Modicon Quantum 140AMM09000 Modicon Quantum Analog I/O 4ch/2ch Module PV:00

Product Details:

Place of Origin: FR
Brand Name: Schneider
Model Number: 140AMM09000

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: T/T, Western Union
Supply Ability: 100
Detailed Product Description
Brand: Schneider Model: 140AMM09000
Palce Of Origin: FR Current: +/- 25 MA
Analogue Input Number: 4 Module Format: Standard
Voltage: 24V Channels: 6
High Light:

analog interface module

,

plc power supply module

Schneider  Electric  Series Modicon Quantum140AMM09000 Modicon Quantum Analog I/O 4ch/2ch Module PV:00

 

 

 

 

Specication 
Part Number 140AMM09000
Manufacturer Schneider Electric
Series Modicon Quantum
Weight 1lb
Type IO Modules
Warranty 2 year
Module format Standard
Type of filter Single pole low pass - 3 dB at 21 Hz +/- 20 % input
circuit
I/O modularity 6 channels
Addressing requirement 2 output words
5 input words
Analogue input number 4
Analogue input type Unipolar voltage 0...5 V 15 bits DC
Unipolar voltage 0...10 V 16 bits DC
Unipolar offset voltage 1...5 V 14 bits DC
Unipolar offset current 4...20 mA 14 bits DC
Unipolar current 0...20 mA 15 bits DC
Bipolar voltage +/- 5 V 15 bits DC
Bipolar voltage +/- 10 V 16 bits DC
Bipolar current +/- 20 mA 15 bits DC
Absolute maximum input +/- 50 V voltage
+/- 25 mA current
Input impedance > 250 Ohm current
> 10 MOhm voltage
Offset +/- 0.0014 % of full scale maximum/°C 0...60 °C input circuit
Gain shift +/- 0.002 of full scale maximum 0...60 °C input circuit
Common mode rejection > 80 dB 50/60 Hz input circuit
Analogue output number 2
Analogue output range 4...20 mA
Analogue output resolution 12 bits
Loop voltage 7...30 V DC output circuit
<= 60 V DC with external resistance output circuit
Voltage drop 7...30 V DC 20 mA
Setting time 900 µs to +/- 0.1 % of the final value output circuit
External power requirement 7...30 V output circuit
Absolute accuracy error +/- 0.20 % of full scale at 25 °C output circuit
+/- 0.05 % of full scale maximum at 25 °C input circuit
+/- 0.03 % at 25 °C input circuit
+/- 0.007 %/°C of full scale maximum at 0...60 °C output circuit
+/- 0.004 % of full scale at 0...60 °C output circuit
Linearity Monotonic +/- 1 LSB output
Monotonic +/- 1 LSB input
2.4 % over range, and - 9.6 % under range current
2.4 % over and under range voltage
Update time 320 ms input circuit
15 ms output circuit
Fault type Status byte output circuit
Overtacking scale (unipolar) input circuit
Open circuit input/output circuit
Isolation between channels 750 V DC for 1 minute
500 V AC for 1 minute
Isolation between channels and bus 750 V DC for 1 minute
500 V AC for 1 minute
Isolation between input channels and output chan- 750 V for 1 minute
nels 500 V for 1 minute
Marking CE
Local signalling 6 LEDs red channel fault
6 LEDs green channel is turned on
1 LED red external fault
1 LED green bus communication is present (Active)
Bus current requirement 350 mA

 

 

 

 


The Timing diagram is shown below. You only need to supply a short 10uS pulse to the trigger input to start the ranging, and then the module will send out an 8 cycle burst of ultrasound at 40 kHz and raise its echo. The Echo is a distance object that is pulse width and the range in proportion .You can calculate the range through the time interval between sending trigger signal and receiving echo signal. Formula: uS / 58 = centimeters or uS / 148 =inch; or: the range = high level time * velocity (340M/S) / 2; we suggest to use over 60ms measurement cycle, in order to prevent trigger signal to the echo signal.

 

 

 

l Attention:
The module is not suggested to connect directly to electric, if connected electric, the GND terminal should be connected the module first, otherwise, it will affect the normal work of the module.
When tested objects, the range of area is not less than 0.5 square meters and the plane requests as smooth as possible, otherwise ,it will affect the results of measuring.

 

 

 

 

140EHC10500 
140EHC20200 
140ERT85410 
140NOM21100 MB+
140XTS00200 
140XBE10000 
140XCA71703 
140XCA71706 
140XCP51000 
416NHM30030A MB+
490NAA27102 MB+ 
490NAA27103 MB+ 
490NRP25300 Modbus Plus
490NRP95400 RIO 
490NOR00003 Ethernet MTRJ-MTRJ 
520422000 
975750000 RIO
990NAA26320 
990NAD23000 MB+ 
990NAD21110 MB+ 
990XCP98000 Quantum CPU 
ASMBII003(15M) RIO
ASMBII004(43M) RIO
MA0185100 
MA0186100 
MA0329001 
TCSESM043F2CU0 ConneXium 
TCSESM083F2CU0 ConneXium 
TCSESM083F2CS0 ConneXium
TCSESM163F2CU0 ConneXium 
TCSESM243F2CU0 ConneXium

 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
 
 
 
 