Shenzhen Wisdomlong Technology CO.,LTD

 

Work hard and best service for you!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsServo Motor Encoder

YASKAWA ENCODER Absolute 17 bit - UTSAE-B17CLE Coupled with couplings for motor

Superb delivery a great product, perfect communication as well !! A++++

—— Carlos

Great deal. Fast shipping and good service.Recommended !!!!!!!!!

—— Gita

I'm Online Chat Now

YASKAWA ENCODER Absolute 17 bit - UTSAE-B17CLE Coupled with couplings for motor

Large Image :  YASKAWA ENCODER Absolute 17 bit - UTSAE-B17CLE Coupled with couplings for motor

Product Details:

Brand Name: Yaskawa
Model Number: UTSAE-B17CLE

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: New in original box
Delivery Time: 2-3 work days
Payment Terms: TT West Union
Supply Ability: 100
Detailed Product Description
Place Of Origin: Japan Brand: Yaskawa
Model: UTSAE-B17CLE Series: UT Series
Resolution: 17 Bit Name Of Series: CL
High Light:

rotary pulse encoder

,

absolute rotary encoder

YASKAWA ENCODER Absolute 17 bit - UTSAE-B17CLE Coupled with couplings for motor

 

 

 

 

 

QUICK DETAILS

  1. Brand :Yaskawa
  2. Model :UTOPI-500UB
  3. Place of Origin :Japan

 


DESCRIPTION

  • Servo Motor Encoder
  • Yaskawa Electric
  • Internal encoders

 

 

Specifications

Manufacturer: Yaskawa

Product number: UTSAE-B17CLE

Vendor number: 500-024-050-1, 500-024-050-3

Description: UTSAE-B17CLE is an Internal encoders manufactured by Yaskawa

Series: UT series Encoders for AC Servo and Spindle motors

Type: Absolute Encoder

Construction of encoder: Coupled with couplings for motor (complete)

Resolution: 17 bit

Name of series: CL

Application or Nodification: E

 

 

 


OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
 
 
 
 
 
SIMILAR PRODUCTS
UTOPE81AWG - Yaskawa - Internal encoders
UTOPI-150VA - Yaskawa - Internal encoders
UTOPI150VA - Yaskawa - Internal encoders
TRD-FWBG13 - Yaskawa - Internal encoders
TRDFWBG13 - Yaskawa - Internal encoders
UTMSH-20ANP - HAAS - Yaskawa - Internal encoders
UTMSH20ANP - HAAS - Yaskawa - Internal encoders
UTMAH-B12AF11 - Yaskawa - Internal encoders
UTMAHB12AF11 - Yaskawa - Internal encoders
UTMAH-B12BF1S - Yaskawa - Internal encoders
UTMAHB12BF1S - Yaskawa - Internal encoders
UTSAE-B17CL - Yaskawa - Internal encoders
UTSAEB17CL - Yaskawa - Internal encoders
UTSIE-B17CK - Yaskawa - Internal encoders
UTSIEB17CK - Yaskawa - Internal encoders
UTOPE-10ANL - Yaskawa - Internal encoders
UTOPE10ANL - Yaskawa - Internal encoders
UTMAE-B12BE5U - Yaskawa - Internal encoders
UTMAEB12BE5U - Yaskawa - Internal encoders
UTSJB-B19BCCBC - Yaskawa - Internal encoders
UTSJBB19BCCBC - Yaskawa - Internal encoders
UTMAE-B12DA5X - Yaskawa - Internal encoders
UTMAEB12DA5X - Yaskawa - Internal encoders
UTMAH-B12AFFJ - Yaskawa - Internal encoders
UTMAHB12AFFJ - Yaskawa - Internal encoders
UTMAH-B12BDMB2 - Yaskawa - Internal encoders
UTMAHB12BDMB2 - Yaskawa - Internal encoders
UTMAH-B12BDYR4 - Yaskawa - Internal encoders
UTMAHB12BDYR4 - Yaskawa - Internal encoders
UTMAH-B12BDYR9 - Yaskawa - Internal encoders
UTMAHB12BDYR9 - Yaskawa - Internal encoders
UTMAH-B12BE5W - Yaskawa - Internal encoders
UTMAHB12BE5W - Yaskawa - Internal encoders
UTMAH-B12EA - Yaskawa - Internal encoders
UTMAHB12EA - Yaskawa - Internal encoders
UTMAH-B12AD3A - Yaskawa - Internal encoders
UTMAHB12AD3A - Yaskawa - Internal encoders
UTMAH-B12BDYR14 - Yaskawa - Internal encoders
UTMAHB12BDYR14 - Yaskawa - Internal encoders
 
 
 
 
 
 
 
Prior to installing the option, wire the drive, make the necessary connections to the drive
terminals, and verify that the drive functions normally. Refer to the Quick Start Guide
packaged with the drive for information on wiring and connecting the drive.
Figure 2 shows an exploded view of the drive with the option and related components for
reference.
 
 
 
A – Insertion point for CN5 G – Removable tabs for wire routing
B – Option card H – Ground wire
C – Included screws I – Drive grounding terminal (FE)
D – Front cover J – Connector CN5-A
E – Digital operator K – Connector CN5-B
F – Terminal cover L – Connector CN5-C
 
 
 
 
ANGER
Electric Shock Hazard
Do not connect or disconnect wiring while the power is on.
Failure to comply will result in death or serious injury.
Disconnect all power to the drive, wait at least the amount of time specified on the drive
front cover safety label. After all indicators are off, measure the DC bus voltage to
confirm safe level, and check for unsafe voltages before servicing. The internal capacitor
remains charged after the power supply is turned off.
 
 

WARNING
Electrical Shock Hazard
Do not remove the front covers of the drive while the power is on.
Failure to comply could result in death or serious injury.
The diagrams in this section may include options and drives without covers or safety
shields to show details. Be sure to reinstall covers or shields before operating any devices.
Use the option according to the instructions described in this manual.
Do not allow unqualified personnel to use equipment.
Failure to comply could result in death or serious injury.
Maintenance, inspection, and replacement of parts must be performed only by authorized
personnel familiar with installation, adjustment, and maintenance of this product.
Do not touch circuit boards while the power to the drive is on.
Failure to comply could result in death or serious injury.

 

 

 

 

 

Contact person: Anna
E-mail: wisdomlongkeji@163.com
Cellphone: +0086-13534205279

 

Contact Details
Shenzhen Wisdomlong Technology CO.,LTD

Contact Person: Anna

Tel: 86-13534205279

Send your inquiry directly to us Message not be empty!